NO | Name | Material | Quantity | Remark |
---|---|---|---|---|
1 | 5mm sensor Tip | PPS | ø5mm | Diameter |
2 | 5mm Probe bolt | SUS 304 | ø6.35mm | Diameter |
3 | 8mm sensor Tip | PPS | Ø8mm | Diameter |
4 | 8mm Probe bolt | SUS 304 | Ø9.6mm | Diameter |
5 | Nut | SUS 304 | select | threads |
6 | Washer | SUS 304 | ø7.9mm | Diameter |
7 | Outer Jacket | Fluoroethylene Propylene(FEP) insulated | ø3.9mm | Diameter |
8 | Wire Armor | SUS 304 | ø9.0mm | Diameter |
9 | Male Coaxial Connector | Gold-plated Brass | ø7.23mm | Diameter |
10 | Cable |
Wire : Silver plated copper Jacket : Fluorethylene |
ø 3.60mm | Diameter |
NO | Name | Material | Quantity | Remark |
---|---|---|---|---|
1 | Washer | SUS 304 | ø7.9mm | Diameter |
2 | Outer Jacket |
Fluoroethylene Propylene(FEP) insulated |
ø3.9mm | Diameter |
3 | Cable Armor | SUS 304 | ø9.0mm | Diameter |
4 |
SMA Connector (Jack) |
Gold-plated Brass | ø7.23mm | Diameter |
5 |
SMA Connector (Plug) |
Gold-plated Brass | ø 3.60mm | Diameter |
6 | Cable |
Wire : Silver plated copper Jacket : Fluorethylene |
ø 3.60mm | Diameter |
Category(Transducer) | Specifications |
---|---|
System Cable Length | 5m or 9m ± 10% |
Calibration Material | AISI 4140 steel |
Linear Range |
2mm(80mils) approx. 0.25mm(10mils) to 2.3mm(90mils) approx. -1 to -17Vdc |
Recommended Gap Setting | 1.27mm(50mils) |
Power |
Requires –17.5Vdc to –26Vdc without barriers at 12mA maximum consumption |
Transducer Output Resistance | 50Ω |
Extension Cable Capacitance | 69.9pF/m |
Transducer Sensitivity | Less than 2mV change in output voltage per volt change in input voltage |
Frequency Response | 0 to 10kHz(-3dB) |
Probe Tip Material | Polyphenylene Sulfide (PPS) |
Probe Case Material | AISI 304 stainless steel(SST) |
Probe Cable |
75Ω triaxial, Fluoro Ethylene Propylene(FEP) Total probe length : 0.5m, 1m, 1.5m, 2m, 5m, 9m |
Extension Cable Material | 75Ω triaxial, Fluoro Ethylene propylene |
Transducer Material | A308 aluminum |
Proximity Probe and Extension Cable Armor |
Flexible AISI 304 SST with FEP outer jacket |
Connector Material | Gold-plated brass or gold-plated beryllium copper |
Mass |
Total System Mass : 0.7kg Probe : 323g Extension Cable : 34g/m Armored Extension Cable : 103g/m Transducer : 246g |
Probe Temperature Range |
Operation Temperature : -45℃ to +180℃ Storage Temperature: -45℃ to +180℃ |
Extension Cable Temperature Range |
Operation Temperature : -45℃ to +180℃ Storage Temperature : -45℃ to +180℃ |
Transducer Temperature Range |
Operating Temperature : -45℃ to +100℃ Storage Temperature : -51℃ to +105℃ |
Relative Humidity | Less than a 3% change |
Category(Transmitter) | Specifications |
---|---|
System Cable Length | 5m or 9m ± 10% |
Calibration Material | AISI 4140 steel |
Linear Range |
2mm(100mils) approx. 0.00mm(0mils) to 2.54mm(100mils) approx. 4 ~ 20 mA |
Recommended Gap Setting | 1.27mm(50mils) |
Power | Requires +24Vdc with barriers at 20mA maximum consumption |
Transmitter Output Resistance | 28.3Ω |
Extension Cable Capacitance | 69.9pF/m |
Frequency Response | 0 to 10kHz(-3dB) |
Probe Tip Material | Polyphenylene Sulfide(PPS) |
Probe Case Material | AISI 304 stainless steel(SST) |
Probe Cable |
5Ω triaxial, Fluoro Ethylene Propylene(FEP) Total probe length : 0.5m, 1m, 1.5m, 2m, 5m, 9m |
Extension Cable Material | 75Ω triaxial, Fluoro Ethylene Propylene |
Transmitter Material | A308 aluminum |
Proximity Probe and Extension Cable Armor |
Flexible AISI 304 SST with FEP outer jacket |
Connector Material | Gold-plated brass or gold-plated beryllium copper |
Mass |
Total System Mass : 0.8kg Probe : 323g Extension Cable : 34g/m Armored Extension Cable : 103g/m Transmitter : 314g |
Probe Temperature Range |
Operation Temperature : -40℃ to +180℃ Storage Temperature: -40℃ to +180℃ |
Extension Cable Temperature Range |
Operation Temperature : -40℃ to +180℃ Storage Temperature : -40℃ to +180℃ |
Transmitter Temperature Range |
Operating Temperature : -40℃ to +100℃ Storage Temperature : -51℃ to +105℃ |
Relative Humidity | Less than a 3% change |