Safety Management System
A system that detects the safety status of workers
and fires in the field using a thermal imaging camera.
A system that uses a thermal imaging camera to notify
the failure or abnormality of machinery.
A system that predicts and diagnoses drive system failures
and abnormalities by analyzing the detection of ambient noise and sound,
and reducing the number of manned work by setting an alarm.
A system that tracks people's movements during manned precise diagnosis and analyzes
and processes long hours of work, requests for help, etc. with video and sound.
Fire detection
Personnel detection
Diagnosis of the condition of machinery (e.g bearings, etc.)
Abnormality diagnosis function
A function to check the location of the abnormal sound
Machine failure rate checking function
Category(Sensor – Microphone) Specifications
Diameter 1/4inch
Housing Material STS304
Output interface BNC
Directivity Omnidirectional
Sensitivitiy See above (0dB = 1v/Pa, 1kHz)
Frequency 20Hz ~ 20kHz
Operating temperature range 0 ~ 99% RH
Operating Humidity Range -26.0dB re 1V/Pa (50mV/Pa)
IP rating IP 44
Category(DAU) Specifications
Number of basic analog input channels (based on card) 4CH
Number of basic analog input channels (based on unit) STS304
Frequency bandwidth according to the number of simultaneous sampling channels Max. 40CH
4CH : 192 KHz
8CH : 96 KHz
16CH : 48 KHz
40CH : 24 KHz
4CH High Speed : 2MHz (option)
Input voltage method DC, AC. IEPE
Input voltage range ±0.2, 2, 20 V
Bias voltage output range of each channel
(For sensor operation)
-24 Vdc ± 2%
Analog output 4~20mA
Digital output/input 16CH / 16CH
Linearity Less than ±0.1%
Range Accuracy Less than ±2%
Resolution Selectable 16 bits / 24 bits
Delta-sigma ADCs
High speed : 16 bits multistage, pipelined ADCs
Dynamic Range 118 dB @ 24 Bits mode
CPU configuration Quad Core 1.4GHz
Storage SATA 256 Gbyte SSD
Transfer interface LAN
Data communication TCP, UDP, FTP
Power AC : AC 100 V to 240 V
Unit Dimension (W*H*D) 19*10.5*14.5 inch (6U rack mount)